BVWBW - CF-100 HARDENER COMPONENT

Product Identification

Product ID:CF-100 HARDENER COMPONENT
MSDS Date:05/08/1991
FSC:8010
NIIN:00N053988
MSDS Number: BVWBW

Responsible Party
AMERICAN SAFETY TECHNOLOGIES INC
565 EAGLE ROCK AVE
ROSELAND, NJ 07068
US

Emergency Phone: 201-403-2600;800-424-9300(CHEMTREC)

Info Phone: 201-403-2600

Preparer: F. LOELOFF

Cage: AMSAT

Contractor
AMERICAN SAFETY TECHNOLOGIES INC.
ROSELAND, NJ 07068 US

Telephone: 800-424-9300

Cage: AMSAT

Ingredients

>2.37

OSHA PEL N/K

ACGIH TLV: N/K


BENZYL ALCOHOL

CAS: 100-51-6

RTECS: DN3150000

OSHA PEL N/K

ACGIH TLV: N/K


PHENOL,2,4,6-TRIS(DIMETHYLAMINO METHYL)-;

CAS: 90-72-2

RTECS: SN3500000

OSHA PEL N/K

ACGIH TLV: N/K


PIPERAZINE,1-(2-AMINOETHYL)-; (N-AMINOETHYLPIPERAZINE)

CAS: 140-31-8

RTECS: TK8050000

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:CAUSES IRRITATION &
CHEMICAL BURNS. SKIN:CAUSES IRRITATION, BURNS, DERMATITIS,
SENSITIZATION AND/OR ALLERGIC SKIN REACTION WHICH CAN BE SEVERE IN
CERTAIN INDIVIDUALS. INHAL:CAUSES NOSE & TH ROAT IRRITATION, &
ALLERGIC RESP REACTION. INGEST:WILL CAUSE ESOPHAGEAL DAMAGE IF
SWALLOWED.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:ALLERGY, ECZEMA & OTHER SKIN
CONDITIONS.

First Aid

First Aid:EYES:FLUSH W/LG AMTS OF WATER FOR @ LEAST 15 MINUTES. GET MED
ATTN. SKIN:REMOVE CONTAMD CLTHG & WASH CONT AREA W/MILD SOAP &
WATER. IF SWELLING OR REDDENING OCCURS, GET MED ATTN. INHAL:REMOVE
TO FRESH AIR. IF BRTHG HAS STOPPED, ADMIN ARTF RESP. GET MED ATTN.
INGEST:IF CONSCIOUS, GIVE LG AMTS OF WATER OR MILK TO DILUTE. DO
NOT INDUCE VOMIT. GET MED ATTN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>200F,>93C
Extinguishing Media:CARBON DIOXIDE, FOAM OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PROUCTS MAY
BE TOXIC.

Accidental Release

Spill Release Procedures:AVOID ALL PERSONAL CONTACT. DIKE SPILL. ABSORB
W/INERT MATL & COLLECT FOR DISPOSAL. FLUSH CONTAMD AREA W/WATER;
PREVENT WASHING FROM ENTERING WATERWAYS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID ALL PERSON CONTACT. DO NOT
EXCEED 110F/43C IN STORAGE AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR WITH ORGANIC
VAPOR CARTRIDGE IF REQUIRED.
Ventilation:MECHANICAL VENT & LOC EXHAUST ARE REC. MECHANICAL EXHAUST
IS NOT REC AS SOLE MEANS OF CONTROLLING EMPLOYEE EXPOS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG & (SUPDAT)
Other Protective Equipment:IN OPERATIONS WHERE CONT MAY OCCUR
COVERALLS, APRON & IMPERVIOUS FOOT COVERING ARE RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EYE PROT:FULL LENGTH FACESHIELD .

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>200F,>93C
Vapor Pres:<1.0 @68F
Spec Gravity:1.02
Evaporation Rate & Reference:<1.0 (BUTYL ACETATE=1)
Solubility in Water:PARTLY MISCIBLE
Appearance and Odor:YELLOW LIQUID, AMINE ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE AND
OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.